謝銘勳Fan Cheng-Yu; Hsieh Justin T.S; Hsieh Ming-Shium; Shih Ying-Chieh; Lee Chian-Her;2026-05-242026-05-242009https://203.71.86.71/handle/123456789/35286Paradoxical anterior movement of the femoral condyles after total knee arthroplasty (TKA) often attenuates the extension mechanism and causes a suboptimal outcome. The medial-pivot implant design aimed to confine anterior movement and emulate physiologic knee kinematics. In our study, a consecutive series of 58 medial-pivot TKA were enrolled with a minimum 5-year follow-up. The Knee Society score improved from 30.5 to 91.1 in objective and from 36.7 to 82.3 in functional scale. The average range of motion was 115.4 degrees . The medial-pivot TKA provided significant improvement in the postoperative range of motion, objective Knee Society score, pain scale, and functional score (P < .05) statistically. A larger sample and longer follow-up are recommended to draw definitive conclusions of this new implant design. (c) 2010 Elsevier Inc. All rights reserved.en-US學科:骨科學科期刊論文PRIMITIVE RESULTS AFTER MEDIAL-PIVOT KNEE REPLACEMENTS A minimum 5-year follow-up studyarticle